Home / Universal Conditioning Chargers (UCC)

Products

Universal Conditioning Charger (UCC)

Attention goes to safety with redundant charge algorithms. Faulty batteries are identified and charge is discontinued.

Universal Conditioning Charger

Robust and Flexible Charger Design

The Cadex Universal Conditioning Chargers (UCC) offer refinements usually not found on competitive chargers. The rugged design stands up to the critical demands of industrial users. Intelligent adapters allow simultaneous service of nickel-cadmium, nickel-metal-hydride and lithium-ion batteries on the same platform. A conditioning button conditions and calibrates batteries on demand, and a reverse-pulse charging prolongs battery life.


Battery Adapter listing for UCC

Field replaceable adapters contain a chip that configures the UCC to the correct algorithm.

BATTERY ADAPTER LIST


UCC 1
UCC 2
UCC 6
ApplicationCommon charging platform configured by programmed battery adapters with discharge function for battery conditioning and calibration
Batteries Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah
Electrical External Power Supply,
90-264VAC, 47-63Hz
External Power Supply,
90-264VAC, 47-63Hz
Internal power supply
90-264VAC, 47-63Hz
Power/Voltage 25W/bay; 14.4V nominal 25W/bay; 14.4V nominal 25W/bay; 14.4V nominal
Temperature Operating: 0°C to 40°C (32°F to 104°F) Operating: 0°C to 40°C (32°F to 104°F) Operating: 0°C to 40°C (32°F to 104°F)
Storage -40°C to 70°C (-40°F to 58°F) -40°C to 70°C (-40°F to 58°F) -40°C to 70°C (-40°F to 58°F)
Charge Time Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h
Charge NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled
Dominions L: 242mm, (9.5")
W: 102mm, (4.0")
H: 64mm, (2.5")
L: 242mm, (9.5")
W: 165mm, (6.5")
H: 64mm, (2.5")
L: 242mm, (9.5")
W: 445mm, (17.5")
H: 89mm (3.5")
Weight 0.3kg, (0.6 lbs.) 0.6 kg, (1.25 lbs.) 3.3 kg, (7.0 lbs.)
Approvals V3.1 CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1. CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1. CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1.
WarrantyCadex warrants the analyzer against defective materials and workmanship for a period of two (2) years from the original purchase date.

ㅤㅤㅤㅤ