Diagnostic chargers, battery analyzers, and rapid testers
Pioneers in Advanced Diagnostic Battery Management (DBM) to care for batteries from workforce to retirement
Reliable partner in quality assurance and engineering
Cadex employs some of the best talent in the industry. We do what we love best and this synergy reflects in creative thinking and strong customer service. Reward comes with buyer satisfaction.
Showing results for
Home / Products /
Universal Conditioning Charger
The Cadex Universal Conditioning Chargers (UCC) offer refinements usually not found on competitive chargers. The rugged design stands up to the critical demands of industrial users. Intelligent adapters allow simultaneous service of nickel-cadmium, nickel-metal-hydride and lithium-ion batteries on the same platform. A conditioning button conditions and calibrates batteries on demand, and a reverse-pulse charging prolongs battery life.
Battery Adapter listing for UCC
Field replaceable adapters contain a chip that configures the UCC to the correct algorithm.
UCC 1 |
UCC 2 |
UCC 6 |
||||
---|---|---|---|---|---|---|
Application | Common charging platform configured by programmed battery adapters with discharge function for battery conditioning and calibration | |||||
Batteries | Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah | Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah | Simultaneous charge of NiCd, NiMH, Li-ion, 3.6V-14V (nominal), 0.5Ah-10Ah | |||
Electrical |
External Power Supply, 90-264VAC, 47-63Hz |
External Power Supply, 90-264VAC, 47-63Hz |
Internal power supply 90-264VAC, 47-63Hz |
|||
Power/Voltage | 25W/bay; 14.4V nominal | 25W/bay; 14.4V nominal | 25W/bay; 14.4V nominal | |||
Temperature | Operating: 0°C to 40°C (32°F to 104°F) | Operating: 0°C to 40°C (32°F to 104°F) | Operating: 0°C to 40°C (32°F to 104°F) | |||
Storage | -40°C to 70°C (-40°F to 58°F) | -40°C to 70°C (-40°F to 58°F) | -40°C to 70°C (-40°F to 58°F) | |||
Charge Time | Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h | Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h | Radio batteries: 2–3h; 5–-6h with Conditioning; large batteries: 7.5h | |||
Charge | NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled | NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled | NiCd/NiMH: Constant Current, Li-Ion: constant voltage, Temperature controlled | |||
Dominions |
L: 242mm, (9.5") W: 102mm, (4.0") H: 64mm, (2.5") |
L: 242mm, (9.5") W: 165mm, (6.5") H: 64mm, (2.5") |
L: 242mm, (9.5") W: 445mm, (17.5") H: 89mm (3.5") |
|||
Weight | 0.3kg, (0.6 lbs.) | 0.6 kg, (1.25 lbs.) | 3.3 kg, (7.0 lbs.) | |||
Approvals V3.1 | CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1. | CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1. | CAN/CSA C22.2 No. 60950-1 Second Edition, ANSI/UL 60950-1. | |||
Warranty | Cadex warrants the analyzer against defective materials and workmanship for a period of two (2) years from the original purchase date. |
ㅤㅤㅤㅤ